Skip to content

Docker 4.12.0 on Windows throws "The pipe has been ended" error #3045

@mndeveci

Description

@mndeveci

Hi team,

We've started to see error messages with Docker Desktop v4.12.0 on Windows. We are attaching to the container by calling {container_instance}.attach(stream=True, logs=True, demux=True) and then iterating through the logs streams. This is working fine with earlier versions but it started to throw following error with Docker Desktop v4.12.0.

Traceback (most recent call last):
  File "c:\users\administrator\workplace\aws-sam-cli\samcli\local\docker\container.py", line 401, in _write_container_output
    for stdout_data, stderr_data in output_itr:
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\types\daemon.py", line 32, in __next__
    return next(self._stream)
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\api\client.py", line 406, in <genexpr>
    gen = (demux_adaptor(*frame) for frame in gen)
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\utils\socket.py", line 94, in frames_iter_no_tty
    (stream, n) = next_frame_header(socket)
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\utils\socket.py", line 66, in next_frame_header
    data = read_exactly(socket, 8)
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\utils\socket.py", line 51, in read_exactly
    next_data = read(socket, n - len(data))
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\utils\socket.py", line 35, in read
    return socket.recv(n)
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\transport\npipesocket.py", line 23, in wrapped
    return f(self, *args, **kwargs)
  File "c:\users\administrator\workplace\aws-sam-cli\venv\lib\site-packages\docker\transport\npipesocket.py", line 117, in recv
    err, data = win32file.ReadFile(self._handle, bufsize)
pywintypes.error: (109, 'ReadFile', 'The pipe has been ended.')

A simplified version of how we are reading the logs;

# stdout and stderr are StreamWriter's that is been provided earlier
logs_itr = container.attach(stream=True, logs=True, demux=True)

for stdout_data, stderr_data in output_itr:
  if stdout_data and stdout:
    stdout.write(stdout_data)

  if stderr_data and stderr:
    stderr.write(stderr_data)

See related issue here: aws/aws-sam-cli#4222

Thanks!