Notifications
You must be signed in to change notification settings - Fork 26
Description
Issue Summary:
When using the PrevTickBefore
function with a specific cron expression and a reference time within the same year, the function unexpectedly returns an "unreachable year segment" error. This occurs even when the year in the cron expression matches the reference time year.
Expected Behavior:
Given the cron expression "30 15 4 11 * 2024"
, which schedules a job for November 4, 2024, at 15:30, and a reference time of November 8, 2024, at 22:18:16 UTC, calling PrevTickBefore
should return the previous tick of November 4, 2024, at 15:30:00 UTC without any errors.
Actual Behavior:
The function returns an error indicating "unreachable year segment: 2024"
.
Test Case:
Here is a minimal test case that reproduces the issue:
package main
import (
"fmt"
"time"
"github.com/adhocore/gronx"
)
func TestIsUnreachableYear_CurrentYear() {
// Set reference time ("now") to November 8, 2024, at 22:18:16 UTC
now := time.Date(2024, time.November, 8, 22, 18, 16, 0, time.UTC)
// Cron expression for 15:30 on November 4, 2024
cronExpr := "30 15 4 11 * 2024"
// Expected outcome: November 4, 2024, at 15:30
expectedTime := time.Date(2024, time.November, 4, 15, 30, 0, 0, time.UTC)
// Call PrevTickBefore
actualTime, err := gronx.PrevTickBefore(cronExpr, now, true)
// Simplified check for error and time
if err != nil {
fmt.Printf("Test FAILED: Did not expect an error, but got: %s\n", err)
} else if !actualTime.Equal(expectedTime) {
fmt.Printf("Test FAILED: Expected previous tick to be %v, but got %v.\n", expectedTime, actualTime)
} else {
fmt.Println("Test PASSED: Year segment 2024 is reachable, and PrevTickBefore returned the correct previous tick.")
}
}
func main() {
TestIsUnreachableYear_CurrentYear()
}
Steps to Reproduce:
- Use the above test case, which calls
PrevTickBefore
with a reference time (now
) in November 2024 and a cron expression for November 4, 2024, at 15:30. - Observe that the function returns an "unreachable year segment" error instead of providing the expected previous tick time.